What is AUTOMATION
• Making products under the control of computers and programmable controllers is known as automation.• Manufacturing assembly lines as well as stand alone
machine tools and robotic devices fall into this category.• It is delegation of human control functions to
technical equipment for increasing the productivity, quality, and increasing the safety in working conditions thereby reducing the manpower and cost.
![Page 3: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/3.jpg)
INSUSTRIAL AUTOMATION
• Now a days, every small and large industry employ automation.• In manual control, an operator periodically reads the
process and adjusts the input accordingly. Quite hectic!• In automation control, measurements and adjustments
are done automatically on a continuous basis. Quite convenient!
![Page 4: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/4.jpg)
Types of Control Systems used in INDUSTRIAL AUTOMATION
• PID controller based control system• PLC based control system• DCS based control system• PC based control system
![Page 5: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/5.jpg)
PLC(Programmable Logic Controller)
• It is microprocessor based solid state/industrial computer that perform discrete or sequential logic.• It was developed to replace mechanical relays,
timers, counters.• The early PLC’s were used to reduce the changeover
time, wiring/re-wiring.• The PLC programming procedures replaced the
rewiring a panel full of wires, relays, timers, counters etc.
![Page 6: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/6.jpg)
Advantages • Reliability in operation.• Flexibility in control and programming techniques.• Online offline modifications.• Small physical size, shorter project time.• In house simulation and testing of project.• Speed of operation.• Ease of maintenance and troubleshooting.• Ability to communicate and networking with computer system in
plant.• Documentation and security.• Designed to work in all types of industrial conditions.
![Page 7: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/7.jpg)
Micrologix 1000 programmable controller
![Page 8: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/8.jpg)
Architecture of a PLC• BLOCK DIAGRAM
INPUT DEVICES PLC OUTPUT
DEVICES
POWERSUPPY
MEMORY INTERFACE
(24V DC,120V AC)
(Toggle or Push buttons, proximity or pressure sensors) (Displays
& Monitors)
(External memory module)
(SCADA or HMI)
![Page 9: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/9.jpg)
Hardware Overview
![Page 10: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/10.jpg)
![Page 11: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/11.jpg)
COMPUTER PLCDOWNLOAD
UPLOAD
• DATA TRANSMISSION-SERIAL
• SYSTEM(PORT) PLC(PORT) RS 232 DF port
• Baud Rate- 9.6 Kbps to 19.2 Kbps
• Driver softwares- RS Linx Classic, RS 232 & DF Drivers
• Programming software- RS Logix 500
![Page 12: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/12.jpg)
Working• Source mode: +ve supply is given to the PLC.• Sink mode: -ve supply is given to the PLC.
• The sink and source modes mainly define the way in which the I/O is connected to the I/O of the PLC.
![Page 13: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/13.jpg)
PROGRAMMING the PLC• Programming language used: LADDER
language( ladder 2). The programming can be done with simple contacts that simulate the opening and closing of relays, counters, timers, shift registers and other math operations.
![Page 14: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/14.jpg)
![Page 15: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/15.jpg)
Basic symbols:• Input symbols: XIC- XIO-
• Output symbols: OTE- OTL-
OUL-
![Page 16: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/16.jpg)
START- STOP LOGIC:• START: hardware software NO- NC-
• STOP: NO- NC-
![Page 17: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/17.jpg)
ADDRESSING FORMAT : Identifier: slot address(if any).word address/bit
DATA FILES: micrologix 1000 contain the status information associated with the external I/O and all other instructions we use in our main and subroutine ladder program files.
These files are organized by the type of data they contain. Data file types are:
![Page 18: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/18.jpg)
PLC TIMER/COUNTER FUNCTION
![Page 19: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/19.jpg)
TIMER ON(Ton)
![Page 20: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/20.jpg)
COUNTER UP
![Page 21: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/21.jpg)
MATH INSTRUCTIO
NS
![Page 22: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/22.jpg)
![Page 23: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/23.jpg)
OTHER IMPORTANT INSTRUCTIONS• JMP• JSR• SBR• CMP• MOV• OSR
![Page 24: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/24.jpg)
Applications
• Material Handling• Packaging Applications• General Industrial Machinery• Printing• Food and Beverage• Pharmaceutical• Water Wastewater / SCADA• Clutch/Brake control• Position Control - Pick-and-place / Conveyor
![Page 25: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/25.jpg)
SCADA
• Supervisory Control And Data Acquisition• It is a software through which we can create
visualization of any industrial process.• Earlier, PLC’s were programmed, download the
program in it and it used to run for years• The problem- no one knew what’s happening inside
the PLC.• Solution= PLC+SCADA
![Page 26: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/26.jpg)
TAG’s• It is the address of the memory location where signals are
being saved.• We define a TAG in order to use it in the SCADA
software(Intouch wonderware).• TYPES : 1) Analog 2) Digital 3) Strings • These are further associated with either “Memory” or “I/O”
type tags.• PC-SCADA – Memory analog/digital/string tag• PLC-SCADA - I/O analog/digital/string tag
![Page 27: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/27.jpg)
FEATURES OF SCADA
• Dynamic process graphic• Alarm• Database connectivity• Real time trend and historical trend view• Security• Device connectivity
![Page 28: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/28.jpg)
SCADA Software
• Wonderware- Intouch• Rockwell- RS view32• Siemens- winCC• GE- Intellation
![Page 29: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/29.jpg)
![Page 30: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/30.jpg)
![Page 31: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/31.jpg)
PLC-SCADA COMMUNICATION
![Page 32: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/32.jpg)
EXAMPLE
![Page 33: PLC & SCADA](https://reader033.vdocumenti.com/reader033/viewer/2022061507/587c94421a28abfa5e8b5bfd/html5/thumbnails/33.jpg)
THANK YOU !!!